3 – Unscrew the ring nut (C).
4 – Use the screw (D) (cleaning system water) to bring the pressure reading on the
pressure gauge (E) to 1,5 bar. €
If the water pressure is too low, install a device to increase the pressure.
5 – Retighten the ring nut (C).
6 – Unscrew the ring nut (F).
7 – Turn the cooking chamber water intake screw (G) to bring the pressure reading on
the pressure gauge (H) to 1 bar.
If the water pressure is too low, install a device to increase the pressure.
8 – Retighten the ring nut (F).
9 – Replace the panel (A) and screw the screws back into place.
10 – Turn the water supply tap (B) back off when the operation is complete.
IT
RECOMMENDATIONS FOR REPLACING PARTS
Before carrying out any replacement procedure, activate all the safety devices provid-
GB
ed and decide whether staff at work and those in the vicinity should be informed. In
particular, turn off the water supply tap, cut off the electricity supply using the master
DE
switch and prevent access to all devices that might cause unexpected health and safe-
ty hazards if turned on.
FR
If worn parts have to be replaced, use original spare parts only.
ES
The manufacturer declines all responsibly for injury or damage to components due to
the use of non original parts, or extraordinary work on the appliance which may modify
the safety requirements without the manufacturer's authorisation.
When ordering components, follow the instructions provided in the parts catalogue.
English
H
G
F
C
D
REPLACING PARTS
A
E
- 60 -
B
Use and installation manual
9