ELECTRICAL CONNECTION
Caution - warning
The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specified materials.
The appliance "FX 201 E3" is supplied with operating voltage 400V/3N/PE, which
can be switched to 230V/3/PE.
The appliance "FX 202 E3" is supplied with operating voltage 400V/3N (50-60
Hz), which cannot be switched to other values.
(see attached wiring diagrams)
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply
as follows.
1 – If not already present, install an automatic circuit-
breaker (B), close to the appliance, with the following
characteristics.
– Thermal breaker device (to adjust see table on
page 5).
– Differential breaker set at 30 mA
– Class B or C (IEC 898)
2 – Undo the screws and remove the side panel (A).
3 – Connect the automatic circuit-breaker (B) to the
appliance's terminal board (C) and to the electrical
mains supply, in accordance with the electrical
system diagram provided at the back of the manual
and using a cable with the following characteristics.
– Weight:
than H05RN-F type (designation 245 IEC
57)
– Temperature of use:
70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
4 – Replace the panel and retighten the screws when the operation is complete.
CONVERSION OF ELECTRICITY SUPPLY (FX 201 E3)
Caution - warning
The appliance is supplied with operating voltage
400V/3N (indicated on the sticker applied to the
dataplate); it can be converted to 230V/3 as de-
scribed below (this model only).
To carry out this operation, proceed as follows.
1 – Disconnect the mains electricity supply.
2 – Undo the screws to remove the side panel (A).
3 – Fit the jumper (B) to make the electrical
connection of the terminals (C-D) (see attached
wiring diagrams).
English
C
B
C
D
- 57 -
B
A
IDM-39619201200.tif
A
IDM-39619201300.tif