Safety defects due to improper accessories and spare parts
The use of accessories and spare parts, detachable parts or materials that are
not recommended by Löwenstein Medical GmbH & Co. KG and specified in the
instructions for use may compromise the safety and function of the device. Any
warranty is excluded for damage caused by using accessories and spare parts
not recommended or by improper use.
Only use original accessories and spare parts.
Warning of safety defects due to improper connections of the ME
system
The connection of the ME system with other devices or installations resp. pieces
of equipment not recommended by Löwenstein Medical GmbH & Co. KG and
not specified in the instructions for use may compromise the safety and function
of the ME system. Any warranty is excluded for damage caused by connecting
devices or installations resp. pieces of equipment not recommended with the
secretion aspirator Allegra M30 or by improper use.
Only connect recommended original parts with the
secretion aspirator Allegra M30.
Damage of the device by heat
Do not cover the power supply unit.
Keep the aspirator as well as the mains cable and the power supply unit
away from other heat sources.
Always position the aspirator a sufficient distance away from other devices
which generate heat (e.g. not directly in front of a cooling fan opening) to
prevent the aspirator heating up excessively.
Damage of the device due to improper handling
Never aspirate flammable, corrosive or explosive liquids or gases.
Do not drop the device.
Prior to each use check the housing for any damage and do not operate the
device in case of apparent housing damage.
Prior to each use check the suction tube, secretion canister and bacterial
filter and if applicable any other accessories, that are subject to wear and
damage, to ensure that the components are in a perfect condition and
proper operation of the device is guaranteed. If this is not the case, replace
the parts immediately.
All manuals and user guides at all-guides.com
Inspection of the internal power supply
Since the internal battery is not maintained automatically in a fully operational
state, it is necessary to check the charging status regularly and if necessary, the
battery must be replaced by service staff. The battery may only be replaced by
trained service staff, since the replacement by inadequately trained personnel
could result in a hazard (such as excessive temperatures, fire or explosion)!
Possible physiological effects and unobvious risks
Select the vacuum range depending on the respective patient and on the
medical indication to avoid personal injuries.
During the aspiration procedure, ensure that the device is in an upright
position to prevent the secretion canister overflowing.
Always place the device upright on a sturdy and flat base without slope.
Make sure that the device cannot be knocked over or fall in such a way that
persons could be hit by the falling device.
Only operate the device with inserted vacuum pump and closed lid. The lid
above the vacuum pump may only be opened by adequately trained service
staff! Likewise, the vacuum pump may only be replaced by adequately
trained service staff.
Other devices, examinations or treatments may possibly be influenced by
the device. For this reason, special attention should always be paid to other
devices as well as to examinations and treatments performed in parallel so
that any influence is detected as quickly as possible.
When using the device, adequate lighting must always be ensured so that all
labels can be identified clearly.
Small, detached parts could be inhaled or ingested. Therefore ensure that
no unauthorized persons, children or pets are near the device.
Although the materials used have been tested for compatibility, in excep-
tional cases allergic reactions to the exposed materials on the device and
its accessories may occur. This applies especially for contact injuries after
prolonged contact. In such cases, turn to a doctor immediately.
1 User information