RS-232C
$ Query control commands
Data transmitted by PC
[STX] QRA [ETX]
[STX] QRE [ETX]
[STX] QRF [ETX]
[STX] QRR [ETX]
[STX] QRS [ETX]
[STX] QRV:m [ETX]
Parameter
m =
D: ROM version of digital video
microcomputer
S: Version
of
servo
syscon
microcomputer
I: ROM version of interface
No parameter:
ROM version of interface
Data returned from unit in response
[STX] RAm [ETX]
m = N: ACK ON
F: ACK OFF
[STX] LRBm [ETX]
Parameter
m = F: Buzzer OFF
0: 5 minutes
1: 10 minutes
2: 20 minutes
3: 30 minutes
[STX] LNRf:p:t [ETX]
Parameter
f = I: Field recording
R: Frame recording
p = H: HIGH
Recording at a high picture
quality
N: NORMAL
Recording at the standard
picture quality
t = 0—7: Recording type (RT0—7)
[STX] LRRm [ETX]
Parameter
m = N: REC REVIEW is performed
automatically.
F: REC REVIEW OFF
[STX] RSEm [ETX]
Parameter
m =
0: Normal
1: No command upon completion
2: No command upon
completion/when an error has
occurred
[STX] VERdata [ETX]
Parameter
data = d1d2.d3d4-d5d6-d7.d8d9
d1—d9: Software version
97
Description of command
Queries the ACK (acknowledge) code response setting.
Queries the setting of the buzzer operation in the event that
the unit is kept in the stop mode for a prolonged period of
time.
Queries the recording mode, picture quality and recording
type settings.
Queries the REC REVIEW setting.
Queries the search end mode setting.
Queries the versions of the software used with each of the
microcomputers.