Terminal signal levels
External interface preparation
specifications
Example of lamp lighted by HIGH signal
Power
Control signal
GND
O Use devices with ratings which support the actual
operating conditions.
Terminal
Signal level
ALARM IN
T
V
IH
1/2
V
IL
V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms
ALARM
T
RESET IN
V
IH
V
IL
V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms
ALARM OUT
V
OH
V
OL
V OH = 11.0 V to 13.0 V
V OL = 0.0 V to 0.6 V
4.7 kΩ pull-up resistor (+12V) output
REC IN
T
V
IH
V
IL
V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms
EXT TIMER
T
V
IH
IN
V
IL
V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T: Recording time
EXT TIMER
OPEN
T
OUT
V
OL
V OL = 0.0 V to 0.6 V
(Lamp, etc.)
Relay
Remarks
Ground input
High input
Ground output
The output format is
set using the
ALARM/SENSOR
OUT item on the
menu screen shown
on P7 TERMINAL
OUTPUT SELECT.
Ground input
Ground input
Recording is
performed during
the V IL input (T).
Ground output
OPEN
Output time T is set
using the EXT
TIMER OUT item on
the menu screen
shown on P7
TERMINAL
OUTPUT SELECT.
Terminal
Signal level
TIME ADJ IN
T
V
IH
V
IL
V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms
TAPE END
V
OH
OUT
V
OL
V OH = 11.0 V to 13.0 V
V OL = 0.0 V to 0.6 V
4.7 kΩ pull-up resistor (+12V) output
WARNING/R
V
OH
EC OUT
V
OL
Open drain output
V OL = 0.0 V to 1.0 V
Max. 200 mA drive enabled
38
Remarks
Ground input
Ground output
T
When REPEAT has
been selected as
the (TAPE END)
MODE setting on
the menu screen
shown on P5 (VTR
MODE SELECT),
output time T is 2
seconds. If a setting
other than REPEAT
is selected, the
signal will continue
to be output until
one of the function
buttons is pressed.
The signal will
continue to be
output until one of
the function buttons
is pressed also
when a setting other
than OFF has been
selected as the
LEVEL setting on
the menu screen
shown on P6 TAPE
REMAIN.
Ground output
T