Useful functions
Alarm memory recall and power
loss memory recall
Alarm memory recall is a function for storing in the
memory those dates/times and number of occasions
on which the alarm recording and sensor recording
functions were activated.
Power loss memory recall is a function for storing in
the memory those dates/times and number of
occasions on which the primary power supply was
shut off due to a power outage, etc.
1
2
2
1
4
6
5
H
2
1
Set the POWER switch to ON.
2
Set the PROGRAM switch to the MENU position
while holding down the STOP button.
The ALARM RECALL screen and POWER LOSS
MEMORY screen now appear.
The alarm number/s and dates/times when the
alarm signal was input are displayed on the
ALARM RECALL screen.
The number of times the primary power source has
been shut off and the dates/times when this
happened are displayed on the POWER LOSS
MEMORY screen.
(Data is displayed in sequence with the latest at
the top of the screen.)
[ALARM RECALL]
29
12 – 30 – 2000
28
12 – 04 – 2000
27
10 – 25 – 2000
26
9 – 10 – 2000
25
8 – 11 – 2000
24
5 – 10 – 2000
23
4 – 11 – 2000
22
3 – 10 – 2000
[POWER LOSS MEMORY]
14
12 – 01 – 2000
13
10 – 05 – 2000
12
08 – 10 – 2000
11
3 – 02 – 2000
RESET button
4
3
;
3
<
4
3
H
1
3:15
12:10
2:20
2:30
6:55
3:22
6:55
3:22
12:00
10:30
9:20
7:00
The following display appears when alarm recording
was never performed or when the primary power
supply was never shut off.
[ALARM RECALL]
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
[POWER LOSS MEMORY]
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
¢¢ ¢¢–¢¢–¢¢¢¢
<Notes>
O Data for up to 8 alarms is stored on the ALARM
RECALL screen whereas data for up to 4 power
losses is stored on the POWER LOSS MEMORY
screen.
O A total of 99 alarms and 99 power losses are stored
in the memory.
When 99 is exceeded, the count returns to "00."
O As with alarm recordings, the sensor recordings are
stored as alarm memory data.
O The alarm memory data and power loss memory
data are stored in the memory circuit inside the unit.
They are not recorded on the tape.
O When the PROGRAM switch is set to any position
except MENU, the ALARM RECALL screen and
POWER LOSS MEMORY screen displays are
cleared.
O When the RESET button is pressed while the
ALARM RECALL screen is displayed, the memory
can be cleared, but the POWER LOSS MEMORY
screen is not cleared.