Terminal connections
Tape-end output connections
External
interface
1 2
GND
IN OUT
IN
RESET
OUT
EXT
TIMER
ALARM
REC IN
GND TIME ADJ IN
When the cassette tape comes to its end during
recording, the alarm device which has been installed
externally is triggered.
Auto OFF output connections and
recording output connections
1 2
GND
IN OUT
IN
RESET
OUT
EXT
TIMER
ALARM
REC IN
GND TIME ADJ IN
The auto OFF output and recording output
connections are the same. Select between them
using ERROR WARN/REC OUT on the menu screen
shown on P7 TERMINAL OUTPUT SELECT.
Auto OFF output
When a problem has occurred in the unit, the alarm
device which has been installed externally is
triggered.
In this case, the error code appears on the display.
(See page 102.)
Recording output
When the unit is set to the recording mode, the alarm
device which has been installed externally is
triggered.
Alarm lamp
WARNING
/REC OUT
TAPE END OUT
External
interface
Alarm lamp
WARNING
/REC OUT
TAPE END OUT
External timer input connections
External timer
1 2
GND
IN OUT
IN
RESET
OUT
EXT
TIMER
ALARM
REC IN
An external timer can be used for recording.
O Select ON for EXT TIMER IN on the menu screen
shown on P7 TERMINAL INPUT SELECT, and set
the front panel TIMER MODE button to EXT
(external timer recording).
The unit's power is turned off, and recording is
started by the signal from the external timer.
External timer signal
Power OFF
Recording proceeds in the recording
mode which was set by menu screen P4
RECORDING MODE.
36
WARNING
/REC OUT
TAPE END OUT
GND TIME ADJ IN
External timer
Power OFF
recording

Publicité