Setting menus
Menu page P4
[RECORDING MODE]
FIELD/FRAME
FIELD
PICTURE QUALITY
HIGH
REC-TYPE
RT0 ( OFF¢16)
[ALARM/SENSOR REC]
MODE
OFF
FIELD/FRAME
FIELD
PICTURE QUALITY
HIGH
DURATION
0.5min
BUZZER
OFF
REPEAT
OFF
GROUP ALARM1
RT0 ( OFF¢16)
GROUP ALARM2
RT0 ( OFF¢16)
ALARM/SENSOR REC screen
P4
Menu item
MODE
For setting what recording operation is to be performed when an
alarm signal has been input.
OFF
ALARM/SENSOR:
ALARM : Alarm recording is performed.
SENSOR: Sensor recording is performed.
FIELD/FRAME
For selecting field recording or frame recording when alarm
recording or sensor recording is to be performed.
FIELD
FRAME : Frame recording is performed.
PICTURE
For setting the picture quality when alarm recording or sensor
QUALITY
recording is to be performed.
HIGH
NORMAL
NO CHANGE : Recording is performed at the current quality setting.
DURATION
For setting the length of the alarm recording or sensor recording.
0.5min
1.0min
1.5min
2.0min
3.0min
5.0min
10min
CONTINUE: Recording continues until the tape-end.
MANUAL
BUZZER
For setting whether the buzzer is to sound during alarm recording or
sensor recording.
ON : The buzzer sounds. It stops when any one of the function
OFF : The buzzer does not sound.
REPEAT
For setting whether alarm recording or sensor recording is to be
performed if an alarm signal has been input while repeat recording is
underway or while the tape is being rewound.
OFF : Alarm recording or sensor recording is not performed when
ON : Alarm recording or sensor recording (or both) is forcibly
GROUP ALARM1
For selecting the recording type from what was registered on menu
page P3 when alarm recording or sensor recording is to be
performed if an alarm signal is input to ALARM IN 1.
RT0—RT7
GROUP ALARM2
For selecting the recording type from what was registered on menu
page P3 when alarm recording or sensor recording is to be
performed if an alarm signal is input to ALARM IN 2.
RT0—RT7
The underlining indicates the factory mode setting.
<Note>
When RT7 has been selected as the REC-TYPE item setting, the
FIELD/FRAME item setting is overridden and frame recording is forcibly
initiated.
44
Description of function
: The unit operates normally regardless of whether an
alarm signal is input.
Alarm recording or sensor recording is performed.
: Field recording is performed.
: Recording is performed at a high quality.
: Recording is performed at the standard quality.
: Recording for 30 seconds.
: Recording for 1 minute.
: Recording for 1 minute and 30 seconds.
: Recording for 2 minutes.
: Recording for 3 minutes.
: Recording for 5 minutes.
: Recording for 10 minutes.
: Recording is performed only while an alarm signal is
input.
buttons is pressed.
the tape is being rewound.
If an alarm signal has been input even when tape rewinding is
completed, alarm recording or sensor recording is performed.
performed even while the tape is being rewound.