2.8
CONJUNCTION OR FUME CONDUCT
The conjunction of the cooker to the flue must be
as short as possible and must not have horizontal
or not much inclined parts. The counterslope parts
are forbidden and must be absolutely avoided.
Near the conjunction, inflammable materials must
not be present. The conjunction must not go inside
2.9
FLUE OUTLET PREDISPOSITION
M-MZ-ML Range models are endowed with the
predisposition of the flue outlet in the upper and
rear parts, right or left. The choice of the side must
be done when ordering the cooker. After the deliv-
ery, it is still possible to change the position from
right to left and from left to right but it is neces-
sary to make some variations inside the cooker in
addition to the replacement of the flue connector.
Picture 9 - Multiflue cooker, predisposition of the correct flue outlet
2.10
CORRECT CONJUNCTION TO THE CHIMNEY
If the conduct of the chimney starts from a lower
floor than the connection point of the cooker, it
may be necessary to close the conduct under the
connection pipe with fireproof materials. If you
have the chimney behind or up, you have to use
the connector with bayonet coupling. This must be
the flue. To increase the safety of the conjunction,
we suggest to install a washer on the wall being
sure that the connection between the washer and
the chimney is walled and well sealed. Also the
connection between the cooker and the conjunc-
tion must be fixed and sealed.
The variation must be done by experienced tech-
nicians. The use of the flue outlet upper or rear
is free and can be chosen by the installer. Before
connecting the cooker, it is necessary to chose the
correct outlet and to verify that the other outlets
are closed, eventually using the caps given as en-
dowment of the cooker.
inserted and turned so that it can remain blocked.
This connector has a tolerance of about 1 cm to
make the installation easier. The tolerance is avail-
able according to a single direction which depends
on the orientation of the connector (see picture
10).
73