10 - Electrical supply
EN
Connection to the electrical power mains
WARNING
This apparatus must be earthed.
The oven is only for domestic use.
The feed voltage and the absorbed power are as indicated on
the data plate attached to the left-hand side upright, which can
be seen when the oven door is open.
Connecting must be carried out by qualified personnel and in
accordance with the regulations currently in force.
The manufacturer can not be held responsible for any
damages to persons or objects caused by failure to observe
these instructions.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
The oven must be connected to the mains through a multipole
circuit breaker with a contact-to-contact gap of at least 3
mm, making sure that the earth wire is not disconnected. For
connecting use a flexible cable remembering to make it long
enough to allow the oven to be removed from its housing unit
when maintenance work is required.
The terminal box is located at the rear of the appliance. If a
new cable is fitted, route it through the clamp and make the
connections as shown in the diagram. The earth wire must be
cut longer than the other wires so that it will be the last to break
off in the event of the cable being tugged.
Having made the connection, tighten the cable clamp and
close the cover of the box.
CABLE TYPES AND MINIMAL DIAMETERS CABLE TYPES
AND MINIMAL DIAMETERS
H05RR-F
H05VV-F
H05RN-F
H05V2V2-F
22
3x1 mm
2
3x1 mm
2
3x1 mm
2
3x1 mm
2