Periods At A Standstill - Bartscher 104.825A Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. with plastic tool, push the "W" button (wash position) through dedicated hole below "ON/OFF" button. (Fig 17)
The blue LED starts to flash. The appliance will carry out a complete washing and rinsing cycle
5. switch off machine and disconnect it from electricity mains and water supply
6. remove evaporator cover panel (Fig. 19)
7. pour sanitizing solution onto top part of evaporator, distribute with a brush, and rinse thoroughly with cold water
8. remove (Fig. 15) and immerse in sanitizing solution for 30 minutes:
• flag support assembly (1)
• ice-cube slide (2)
• overflow pipe (3)
• sprayer bank (4) and side caps (5), after removing them from the bank
• sprayer bank feed pipe (6)
• pump filter (7)
• evaporator cover panel (Fig. 19)
9. wipe container walls and door with sanitizing solution using a sponge and brush
10. drain sanitizing solution remaining in pump body by introducing pressurised water into the suction pipe and checking that the water
exits from the delivery pipe (Fig. 20)
11. thoroughly rinse inner basin, door and container with cold water
12. thoroughly rinse ice-cube slide, evaporator cover panel, sprayer bank and the corresponding side caps, flag support assembly,
overflow pipe, pump filter and sprayer bank feed pipe under running water
13. refit parts previously removed
14. reposition top, securing it to rear panel with the screw, if present
The ice-cube maker can now be reactivated as specified in the instruction manual.
IMPORTANT: All the ice produced during the first five cycles after cleaning and sanitizing operations must be discarded.

14 PERIODS AT A STANDSTILL

If you do not intend to use the appliance for a certain period of time, proceed as follows:
• switch off the electric power source by means of the switch (7 in Fig. 4), and remove the plug of the appliance from its socket (if any)
• shut off the water supply by turning off the water supply tap (8 in Fig. 4)
• carry out all the operations envisaged for scheduled maintenance of the appliance (see chapter 9)
• empty the internal basin by raising the flaps (if any) and removing the overflow pipe
• empty out the pump body by blowing compressed air into the pipe that supplies water to the sprayer bank
• clean filter of water supply solenoid valve as described in chapter 9.1
• clean filter of air condenser (if any) as described in chapter 9.2