Programming Scenarios
Scenarios are groups of operations set by the Installer which allow the User, via the control unit, keypad, reader or phone, to:
•
turn areas on / off
•
activate / deactivate outputs
Some scenarios are pre-set at the factory .
CREATING SCENARIOS
It is not necessary to create an identical scenario for each keypad or reader . It is enough to create a single scenario and then associate it
with the different control devices .
08:23
16/05/10
ENTER CODE
WAITING
*=USER MENU
SCENARIOS
03
*
MODIFY SCEN.XX
SCENARIO XX
*
AREA OPERATION
EXACT ON+OFF
▲ ▼
ASSOC. AREAS
XX
---
ASSOC. AREAS
XX
###--
▲ ▼
OUTPUT OPERAT.
DISABLED
▲ ▼
ASSOC. OUTPUT XX
NO
▲ ▼
STEP 1: Selecting scenario
123456
1 .
To access the Technical menu hold down key
222222
by the User code (if less than 6 digits confirm with
2 .
Hold down key
3 .
With
▼ ▲
4 .
With
means the scenario index number) and press
▼ ▲
STEP 2: Operation on areas (not available in EASY mode)
Defines the operation to be carried out on the areas (switch on / off) .
1 .
Staying in the Scenario Menu .
XX
+ -
2 .
With
3 .
With
sic scenario; with it you can set the on/off status of the control unit "exactly"
as described by
4 .
The areas selected will switch on and those deselected will switch off .
STEP 3: Associated areas
1 .
With
2 .
Press the number key relating to the address of the area to be set, then add
1 2 3
#
(# = enabled, - disabled) .
STEP 4: Operation on outputs (not available in EASY mode)
It defines the operation to be carried out on an output (on / off) when the scenario
is launched .
XX
1 .
Staying in the Scenario Menu .
2 .
With
3 .
With
concern only the areas, if you need to activate an output do the following:
a . Set
b . With
c . With
/ESC # for 5 secs and enter the Technical code .
SCENARIOS
select
and press
select the scenario to create/modify
AREA OPERATION
select
EXACT ON+OFF
+ -
set the parameter to
ASSOCIATED AREAS
ASSOCIATED AREAS
select
OUTPUT OPERAT.
select
+ -
set the parameter to
OUTPUT OPERAT.
ON
to
.
ASSOCIATED OUTPUT
select
+ -
set the output to be activated .
/ESC # for 5 secs followed
*
) .
*
.
MODIFY SCENAR.XX
*
.
.
. We will use the clas-
.
.
.
DISABLED
. Normally the scenarios
.
XX
(