fig . 3
Install the control unit far from access points and somewhere it is hard to identify .
Secure onto a suitable wall that can permanently support the control unit .
Prepare the holes and channel for the cables to pass through before installation .
Use the 4 special holes for mounting it on the wall .

CABLING

230 V AC
Disconnect the circuit breaker associated with the control unit before cabling the 230 V AC network and for the whole time that the
control unit is open .
Connect the 230 V AC Line and Neutral cable to the transformer's terminals .
Lock the 230 V AC power supply cable to the container so that it cannot move even if the terminals are disconnected .
Before closing the control unit always check that all metal parts are earthed .
fig . 4
0Vca - 22,9Vca
SEC
230Vca - 50Hz
L
N
• attach the base of the container securely to
the wall, making sure that the switch (shown in
figure 4) with anti-tamper function can spring
correctly .
• The special holes in the bottom of the con-
tainer can be used to pass the cables through
or the ready made slot in the upper part of
the container can be opened (with the aid of
a hacksaw) .
• Position the battery in the relevant housing
and proceed with the wiring .