Pressing button
causes LED 3 to light up and prepares for the launch of scenario 3 associated with the keypad .
After selecting the scenario to launch, just press button
The control unit will start the exit time . If the inputs are not open, just press button

Silencing the alarm

Key in the user code . A beep will confirm the code is correct .

LIGHT SIGNALS

LEDs
STATUS
INFORMATION
1 (green)
The associated scenario is activated or is being activated .
2 (green)
The associated scenario is not activated .
3 (green)
During arming or with the system armed, one or more inputs that belong to the scenario are open .
At least one area associated with one of the three scenarios will be disarmed .
4 (red)
All the areas associated with the 3 scenarios will be disarmed .
The control unit is in alarm or memory alarm mode .
〇 = Off | ● = On | ◉ = Flashing
With the system disarmed, if there are open inputs in areas associated with the keypad, the three green LEDs will be flashing
PXITU READER
m
The readers must be mounted in an area protected from break-ins or an area under surveillance by the system. If not, the
reference standard is not valid.

Characteristics

Power supply voltage (V DC)
Max . power draw (mA)
Min . power draw (mA)
Operating temperature (°C)
Dimensions
Protection rating (IP)

DESCRIPTION

PXITU
1
B
.
The reader takes up only one module in the switch boxes of any domestic installation .
RS-485 bus terminals for connecting keypads, remote modules and readers .
[+,-] bus power supply .
+ A B –
[A,B] data .
64330380
PXITU
1
System status light signals
2
Sensitive zone for transponder key (see system management section)
again to force the exit time to zero .
PXITU
12 - 15
100
40
-10÷+40
IP40