Cabling Inputs - CAME PXC08 Manuel D'installation

Masquer les pouces Voir aussi pour PXC08:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CABLING INPUTS

Balances are achieved with 4 .7 kohm resistors .
CONNECTING INPUTS
NORMALLY OPEN (NA)
SINGLE BALANCE (SB)
DOUBLE BALANCE SENSOR (DB) WITH MICROWAVE BLOCK WHEN CONTROL UNIT OFF (TC)
Output U1 yields a positive with output on (ON=13 .8 V DC) . Output U1 is factory set as TC (output on when system off and off during exit
time and when at least one area is on) .
Yellow
4
Purple
7
Red
x100
Gold
5%
NORMALLY CLOSED (NC)
DOUBLE BALANCE (DB)
4 .7
kohm
resistor
at
5%

Publicité

Table des Matières
loading

Table des Matières