System Start-Up; First Switch-On / Preliminary Checks; System In Maintenance / Operation Mode; Change Control Unit Language - CAME PXC08 Manuel D'installation

Masquer les pouces Voir aussi pour PXC08:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

System start-up

This section has the objective of describing the start-up of a "simple" system with no special settings, showing the installation of all the
components and the programming of the basic functions (areas, scenarios, inputs, outputs, telephone notifications) .
Before starting up the system the following must have been completed:
Laying control unit bus RS485 .
Cabling inputs .
Cabling outputs .
Cabling control unit .
Cabling keypads, readers, accessories, ...
The start-up of the system is explained below .

First switch-on / PRELIMINARY CHECKS

Check the connection to earth and to the primary 230 V AC power supply .

SYSTEM IN MAINTENANCE / OPERATION MODE

In order to avoid unwanted activations of sirens or telephone calls during system maintenance, it is possible to disable these functions by
putting the system into MAINTENANCE mode .
CN3
In maintenance mode the control unit disables:
Voice calls and SMS .
Activating alarm outputs .
P1
Via the User Menu it is still possible, however, to test the disabled functions .
CN6
M6
+
U1 U2 U3 U4 NO
m
AUX
POS
The maintenance status is only displayed on the LCD keypads .
SYSTEM UNDER MAINTENANCE
IN MAINTENANCE
ENTER CODE

CHANGE CONTROL UNIT LANGUAGE

Updating the language also allows the firmware to be updated and can be done using the PX MANAGER programming software or the FW
UPDATER tool .

POWER ON CONTROL UNIT

• Power the control unit with 230 V AC and connect the battery .
• At first switch-on the control unit follows the setting of parameter
.
• Switch off the system by entering the user code
ON
SW1
1 2 3 4
F5
C
NC
O.C
RELAY
First row of the display with the
words "under maintenance"
To change the maintenance/operation status, change the position of
the switch [SW1]
under maintenance
in operation
JP3
M7
T
TAMPER
SYSTEM IN OPERATION
08:23
16/05/10
ENTER CODE
POWER ON CTR-U.
123456
followed by the off key
First row of the display with
date and time of the control unit
which is normally set to
D
.
TOTAL ARMING

Publicité

Table des Matières
loading

Table des Matières