Sime Brava Slim 25 BF Manuel Pour L'utilisation, L'installation Et L'entretien page 74

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type
No.
Description
PAR
25
Auxiliary TA function
PAR
26
Zone Valve / Pump Relaunch Delay
PAR
28
DHW activation delay with solar power
Anti-legionella Function (Only hot water tank)
PAR
29
-- = Disabled
PAR
30
Maximum domestic hot water temperature
PAR
35
Digital / analogue Pressure switch
PAR
40
Modulating Pump Speed
PAR
41
∆T Modulating pump delivery/Return
PAR
47
System pump forcing (only in winter mode)
PAR
48
INST Parameter set to default
In the event of a fault/malfunction the message "ALL" will appear
on the display with the alarm number eg. "ALL 04" (Domestic Hot
Water Sensor Fault).
Before repairing the fault:
– disconnect the appliance from the mains power by setting the
main switch to "OFF"
OFF
74
0 = according to TA
1 = TA Antifreeze
2= domestic hot water
0 = water pressure
1 = water pressure
transducer
2 = water pressure
transducer (only pres-
sure displayed)
-- = No modulation
AU = Automatic 30
0 = Disabled
1 = Enabled
RESET
– as a precautionary measure, close the gas isolation valve.
Repair the fault and start-up the boiler again.
NOTE:
after having repaired the fault, when the alarm number
appears on the display together with the message
figure), press the button
the appliance up again.
Fig. 40
Range
U/M
Step
-
disabled
0 .. 99
Min
0 .. 30
Min
50 .. 80
-
35 .. 67
°C
switch
-
%
.. 100
10 .. 40
°C
-
0 .. 1
-
y
for approximately 3 seconds to start
EN
Default
1
0
1
1
1
0
1
--
1
60
1
1
10
AU
1
20
1
0
-
0