Wiring Diagram - Sime Brava Slim 25 BF Manuel Pour L'utilisation, L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.11

Wiring diagram

V
PI
BLACK
BROWN
L
N
BLUE
CN11
EAR
L
N
F
TRA
PI
V
EAR
EV
SS
SM1-2
To connect the "Air Thermostat" or, alternatively the "Remote Control", remove the bridge
between terminals 5-6.
m
CAUTION
Users must:
– Use an omnipolar cut-off switch, disconnect switch
in compliance with EN Standards which ensures com-
plete cut-off in overvoltage category III conditions (i.e.
where there is at least 3 mm between the open con-
.
tacts)
– Respect the connections L (Live) - N (Neutral).
– Ensure that the special power cable is only replaced
with a cable ordered as a spare part and connected
by professionally qualified personnel.
60
BROWN
BLUE
VD
BLACK
2
EV
CN12
CN13
CN14
F
TRA
Line
Neutral
Fuse (3.15AT - 250V)
Ignition transformer
System pump
Fan
Ignition / Detection electrode
Gas solenoid valve
Domestic hot water sensor
Dual sensor (thermal safety/delivery)
CR
SE
TA
TA2
6
5
4
3 2 1
3
CN15
CN3
CN5
CN6
FLM
VD
TPA
TA-TA2
SE
SAUX
CR
m
CAUTION
Users must:
– Connect the earth wire to an effective earthing sys-
tem. The manufacturer is not responsible for any dam-
age caused by failure to earth the appliance or failure
to observe the information provided in the wiring dia-
grams
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.
SAUX
TPA
SS
SM1
SM2
Flow meter
Diverter valve
Pressure transducer
Air thermostat
External sensor
Auxiliary sensor
Remote control (instead of air thermo-
stat)
.
EN
FLM
Fig. 14

Publicité

Table des Matières
loading

Table des Matières