Main Water Circuit; System Filling; Sensors; Expansion Vessel - Sime Brava Slim 25 BF Manuel Pour L'utilisation, L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.6

Main water circuit

1
2
3
4
6
8
13
M
U
KEY:
M System delivery
R System return
U Domestic hot water outlet
E Domesti hot water inlet
S Safety valve outlet
G Gas supply
Fan
1
Heat exchanger (mono-thermal)
2
Dual sensor (thermal safety/delivery)
3
Combustion chamber
4
Gas valve
5
Domestic hot water heat exchanger
6
Domestic hot water sensor
7
Diverter valve
8
Automatic bleed valve
9
Pump
10
Domestic hot water flow meter
11
Domestic hot water filter
12

System filling

13
System relief valve
14
Water pressure transducer
15
Boiler drain
16
System expansion vessel
17
5.7

Sensors

The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°-
85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435
– External temperature sensor NTC R25°C; 10kΩ β25°-85°C:
3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω
TR=80°C → R=1669Ω.
58
17
5
9
15
14 S
7
11
12
G
E
R
TR
0°C
1°C
0°C 27279
26135
10°C
17959
17245
20°C
12090
11634
30°C
8313
8016
40°C
5828
5630
4161
4026
50°C
60°C
3021
2928
70°C
2229
2164
1669
1622
80°C
90°C
1266
1232
973
100°C
5.8

Expansion vessel

The expansion vessel installed on the boilers has the following
characteristics:
10
Description
Total capacity
Prefilling pressure
Useful capacity
16
Maximum system content (*)
(*) Conditions of:
Average operating temperature 70°C (with high temperature
system 80/60°C)
Start temperature at system filling 10°C.
Fig. 11
m
CAUTION
– For systems with water content exceeding the max-
imum system content (as indicated in the table) an
additional expansion vessel must be prearranged.
– The difference in height between the relief valve and
the highest point of the system cannot exceed 6 me-
tres. If the difference is greater than 6 metres, in-
crease the prefilling pressure of the expansion vessel
and the system when cold by 0.1 bar for each meter
increase.
5.9

Circulation pump

The flow-head performance curve available for the heating sys-
tem is shown in the graph below.
RESIDUAL HEAD (mbar)
600
500
400
300
200
100
0
0
200
2°C
3°C
4°C
5°C
6°C
7°C
25044
24004
23014
22069
21168
20309
16563
15912
15289
14694
14126
13582
11199
10781
10382
9999
9633
9281
7731
7458
7196
6944
6702
6470
5440
5258
5082
4913
4751
4595
3897
3773
3653
3538
3426
3319
2839
2753
2669
2589
2512
2437
2101
2040
1982
1925
1870
1817
1577
1534
1491
1451
1411
1373
1199
1168
1137
1108
1079
1051
Brava Slim BF
U/M
25
l
8,0
kPa
bar
l
4,0
l
109
25 BF
400
600
800
1000 1200 1400
EN
8°C
9°C
19489
18706
13062
12565
8945
8622
6247
6033
4444
4300
3216
3116
2365
2296
1766
1717
1336
1300
1024
998
30
40
9,0
100
1,0
5,0
124
40 BF
30 BF
1600
FLOW (l/h)
Fig. 12