Engine turns over, Fails to start
Possible Cause
Clogged air filter
Clogged fuel filter
Clogged fuel injector
Kinked or plugged fuel tank vent
No spark to spark plug
Fouled or defective spark plugs
Worn or defective spark plug wires
Incorrect spark plug gap or heat range Set gap to specs or replace plugs
Loose or corroded electrical
connections
Low battery voltage
Old or incorrect fuel
Low or contaminated fuel
Low octane fuel
Crankcase filled with water or fuel
Water present in fuel
Possible Lean or Rich fuel mixture
Fuel is very high octane
Fuel pump is inoperative
Engine turns over, Fails to start
VEHICLE ISSUE DIAGNOSIS
Solution
Inspect and replace as necessary; Replace spark plugs as necessary
Inspect and replace as necessary
See your dealer
Inspect and repair as necessary
Inspect spark plugs, verify stop switch is on
Inspect spark plugs, replace if necessary
See your dealer
Check all connections and tighten
Recharge battery to 12.8 Vdc – Confirm battery health
Replace with 89 minimum octane unleaded fuel
Add or change fuel, clean the fuel system
Replace with minimum 89 octane unleaded fuel
Immediately see your dealer
Replace with 89 minimum octane unleaded fuel
See your dealer
Replace with minimum 89 octane unleaded fuel
Inspect pump and fuse; Replace as necessary
Refuel