10.1.2 - Checking adjustment using radio transmitter
With a radio transmitter which has been memorised in Mode 1, you can
check at any time the adjusted values for each parameter using the fol-
lowing sequence.
To view the parameters in table 5:
01. Press T1 and T2 together on the radio transmitter for at least 5s.
02. Release the two keys.
03. Within three seconds, carry out the action set out in Table 5 based
on the parameter to change.
04. Release the key when the flashing indicator starts flashing.
05. Count the number of flashes and, based on the number, check in
Table 3 for the corresponding value.
Example: If, after having pressed T1 and T2 for 5 s and then T1, the flash-
ing indicator will emit three flashes; the pause time has been programmed
at 40 s.
To view the parameters in table 6:
01. Press T1 and T3 together on the radio transmitter for at least 5s.
02. Release the two keys.
03. Within three seconds, carry out the action set out in Table 6 based
on the parameter to change.
04. Release the key when the flashing indicator starts flashing.
05. Count the number of flashes and, based on the number, check in
Table 4 for the corresponding value.
Parameter
Action
Pause time
Press and hold T1
Pedestrian leaf
Press and hold T2
Motor force
Press and hold T3
"OPEN" function
Press and hold T4
Parameter
Action
Open input configura-
Press and hold T1
tion on the control unit
Flash output configura-
Press and hold T2
tion
Discharge on close
Press and hold T3
Motor 1 and Motor 2
Discharge on open
Press and hold T4
Motor 1 and Motor 2
33
16 – English
TABLE 5
TABLE 6
1
10.2 - OPTIONAL ACCESSORIES
In addition to the devices present in WS200S, there are others available
as optional accessories that can integrate with the automation system.
PR3: 24 V buffer battery; in the event of a lack of mains power supply, this
ensures around ten full cycles.
PF: 24 V solar energy system; useful in cases where power from the fixed
electrical grid is unavailable.
PT50: Pair of 500 mm high columns with a photocell
PT100: Pair of 1000 mm high columns with two photocells
For information on new accessories, refer to the Mhouse product cata-
logue or visit www.niceforyou.com.
DS1: digital selector switch which allows you, after having correctly
entered the secret combination, to control the automation remotely. For
programming see paragraph 10.4.6
10.2.1 - Installing the PR3 buffer battery (fig. 33)
CAUTION! - Electrical connection of the battery to the unit must
be performed exclusively after completing all stages in installation
and programming, as the battery is an emergency power supply.
To install and connect the PR3 buffer battery to the command unit, see
fig. 33 and refer to the PR3 instruction manual.
When automation is powered by the buffer battery, after 60 s following
completion of a manoeuvre, the control unit automatically turns off the
"ECSbus" output (and all the devices connected to it), the Flash output
and all of the leds, excluding the ECSbus led that will flash more slowly;
this is the "Standby" function. When a command arrives, the control unit
will reset to normal functioning (after a brief delay). This feature is designed
to reduce power consumption, as this is a very important consideration
with battery power.
10.2.2 - Install the PF solar power supply system (fig. 34)
CAUTION! - When the automation mechanism is powered exclu-
sively by the "PF" solar power supply system, IT MUST NOT BE
POWERED by the electricity grid at the same time.
To connect the PF solar power supply system to the control unit, see fig.
34 and refer to the PF instruction manual.
When automation is powered by the solar panel, after 60 s following com-
pletion of a manoeuvre, the control unit automatically turns off the "ECS-
bus" output (and all the devices connected to it), the Flash output and
all of the leds, excluding the ECSbus led that will flash more slowly; this
is the "Standby" function. When a command arrives, the control unit will
reset to normal functioning (after a brief delay). This feature is designed to
reduce power consumption, as this is a very important consideration with
solar power.