8) Accessories
"PIU" Card
The control unit is already fitted with all the functions used in a normal installation. In order to allow the system to be used in special instal-
lations, an optional card called "PIU" has been produced which adds new functions such as traffic light signalling, courtesy light, electric
locking, "Photocell2", partial opening and "Phototest".
Red
= Red traffic light
This is normally always off and switches on when
the gate moves.
Green
= Green traffic light
This is normally on and switches off when the
gate moves
Electric lock
= Output for electric lock command.
The electric lock is activated for 1.5 s. at the start
of the opening movement.
Courtesy light/
Phototest
= Output that if used to control the courtesy light,
turns on a courtesy light at the beginning of each
movement which remains on after the movement
has finished for a time programmed with the
T.Cor. trimmer on the "PIU" board.
If the "Phototest" function is activated (Dip-
Switch 10 = ON) this output allows the
photocells to be tested at the beginning of each
manoeuvre.
"RADIO" Card
The control unit features a connector for plugging in a radio card, produced by Nice, which activates the "Step-by-Step" input and allows
the control unit to be remote-controlled with a transmitter.
9) Maintenance
The control unit, being electronic, needs no particular maintenance.
However, periodically make sure (at least once every six months) that
the device adjusting motor force is in perfect working order; adjust
with the trimmer if necessary.
10) Disposal
This product is made from various kinds of material, some of which
can be recycled.
Make sure you recycle or dispose of the product in compliance with
current laws and bye-laws.
14
Partial open
= Input for partial opening (Partial Open, Stop,
Close, Stop). This performs the same function as
the "Step-by-Step" on the main board, with the
difference that the open manoeuvre lasts for the
time set up on the T.AP.P. trimmer on the "PIU"
board.
Photo 2
= 2nd safety device input. This safety device cuts
in just during the opening manoeuvre causing
the gate to stop and eventually close if a
"Semiautomatic" or "Automatic" operation mode
is programmed on the control unit.
24 V
= 24V output used to power services such as
photocells or the like. Terminal 11 is also the
common for the inputs.
Carry out the whole test phase again to check that the limit switches,
safety devices (photocells, pneumatic edges, etc.) and the flashing
light are in perfect working order.
Some electric components may contain polluting
!