––– STEP 6 –––
6.1 - INSTALL AND CONNECT PH100 PHOTOCELLS (fig. 25)
Caution: disconnect the power supply to the system before performing
any installation operations; if the system is equipped with a PR1 buffer
battery, the latter must be disconnected.
Warnings: Be careful not to damage the oring (fig. 25-3) [A].
Choose the positioning of the two elements that make up the photocell
(TX and RX) respecting the following requirements:
• Place them at a height of 40-60 cm above ground, at the sides of the
area to be protected, and as close as possible to the gate wire (no fur-
ther than 15 cm).
• Ducting for passage of the cables must be provided at the intended
point.
• Point the TX transmitter towards the RX receiver, with a maximum mis-
alignment of 5°.
01. Remove the front glass (fig. 25-1).
02. Position the photocell at the point where the cable passage ducting
starts.
03. Mark the drilling points using the bottom as a reference. Drill the
holes in the wall using a hammer drill fitted with a 5mm bit and insert
the 5 mm screw anchors.
04. To pass the electrical cables through holes (made as desired): see
fig. 25-2.
05. Secure the bottom with the relative screws [B] in fig. 25-3 doing
so in such a way that the hole on the bottom [C] in fig. 25-3 corre-
sponds to the cables output. 2 self-tapping screws are also provided
for fixing on surfaces of different densities.
06. Connect the electric cable to the correct terminals, TX and RX (fig.
25-4). From an electrical point of view, TX and RX are connected in
parallel to one another (fig. 25-5) and to the blue terminal on the
25
C
4
10 – English
1 2
3
A
B
control card. You do not need to observe any polarity.
07. Affix the housing cover [D] in fig. 25-6 with the two screws [E] in fig.
25-6 and a Phillips screwdriver. Finally insert the outer cover [F] in
fig. 25-6 closing it with slight pressure.
6.2 - INSTALL AND CONNECT FL100 FLASHING INDICA-
TOR (fig. 26)
Choose the location of the flashing indicator, so that it is in the vicinity of
the gate and easily visible. This may be secured to a horizontal or vertical
surface; fig. 26 shows the two situations:
01. Remove the cover, by unscrewing the screw;
02. Divide the bottom, unscrewing the screws that are used to allow the
electrical cables to pass;
03. Mark the drilling points using the bottom as a reference, and doing
it so that the hole at the bottom corresponds to the cables output:
vertical fixing (A) or horizontal fixing (B);
04. Drill the holes in the wall using a hammer drill fitted with a 6 mm bit
and insert the 6 mm screw anchors;
05. Secure the bottom with the screws;
06. Connect the electrical cables in the relevant FLASH and "antenna"
terminals as shown in the figure: to facilitate the work you can remove
the terminals, make the connections and then reinsert them.
In the FLASH terminal is not necessary to comply with any polarity;
while in the connection of the shielded antenna cable, connect the
sock;
07. Put the lamp door in the base taking care to push it down so that it
locks;
08. Join the body of the flashing indicator to the mounting bracket and
turn to the left until you hear a click, and secure with the screw.
5
6
D
F
E