ARMING WITH OPEN INPUTS
In normal operation it can happen that you want to launch a scenario to arm the system when inputs are open (front door, dormer window,
overhead garage door, etc .) . Some of these inputs will close automatically during the exit time (front door, overhead garage door), while
others (dormer window) will prevent the arming of the associated area .
m
Each area has its own exit time independently of the others . Each area's time is started only when the last open input associated with
the area is closed . Unless you programme an area to switch on in force-start mode (exit time elapses regardless of there being open inputs),
if you leave the house with an input open, the associated area will never be armed .
1.
2.
6.
7.
8. - 9.
$
#
Buzzer with INTERMITTENT sound and flashing green LED means
OPEN inputs .
DISARMING SYSTEM
1.
2.
Disarming the system may be done even during the exit time .
m
The areas that will be disarmed depend on the properties of the key and of the reader .
Example (special case):
Key Areas: 1, 2
Reader areas: 1, 2, 3, 4
Scenario active: GOING OUT (areas 1, 2, 3, 4)
If you use this key to disarm the system, only areas 1 and 2 are disarmed .
1.
2.
3.
3.
4. - 5.
3.
4.
4.
When the red LED light is the only one on it means the system still has areas on .
To launch an arming scenario with open inputs:
1 .
The notification that inputs are open is given even
with the system off, as the 3 green LEDs flash .
2 .
Approach the key to the reading area on the reader .
3 .
Wait for the flash for key recognition .
4 .
The scan in order of the three green LEDs (1, 2, 3, off,
1, 2, . . .) will be started .
5 .
Remove the key when the LED of the scenario that
you want to launch is displayed .
6 .
The red LED comes on and the buzzer starts to make
an intermittent sound (if enabled) and the green LED
will flash to show the exit time with open inputs .
7 .
When all the inputs are closed, the sound will become
continuous, the green LED will come on continuously
and the exit time will start to count down again .
8 .
Once the exit time has elapsed the buzzer switches
off .
9 .
The green LED indicates that the system is on in the
configuration of the scenario launched (in this exam-
ple, no . 2) . If you are viewing the status in screened
mode, after a pre-set time the LEDs will go off .
To disarm the system:
1 .
Approach the key to the reading area on the reader .
2 .
Wait for the flash for key recognition .
3 .
The system status will be displayed (reader with status screen-
ing function) .
4 .
When the LEDs go off, remove the key .