2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Schematic diagram of parameters related to torque, angle, and speed.
Ignore load and don't shut-off
Snug Torque Detection Delay
Switch ON
Angle Before Snug
No Load Speed (1500 to 2300 rpm)
Variable Speed Control (ON, OFF)
Soft Start (ON 100 rpm, OFF)
EN
Snug Torque
Angle
Before Snug
Lower Limit
- 68 -
Torque Upper Limit
Shut-Off Torque
Torque Lower Limit
Angle After Snug
Angle
Before Snug
Upper Limit
Torque
curve
Angle
Angle
After Snug
After Snug
Lower Limit
Upper Limit