2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Snug Point
[Functional overview]
Select a detection method for the snug point. The snug point is used as a reference
point to divide angle results into the one before snug and the one after snug.
When Pulsing Starts:
Snug Torque:
Select From Graph:
[Default value]
When Pulsing Starts
[Setting value]
When Pulsing Starts, Snug Torque, Select From Graph
Detection Threshold (Snug Torque)
[Functional overview]
The point in time when the tightening torque reached this threshold is judged to be the
snug point.
This parameter is enabled only when the snug point setting is "Snug Torque."
Note
• Snug point detection by "Snug Torque" may be less accurate if the absolute value of "Offset_
Intercept" is high.
[Default value]
0.0 Nm
[Setting value]
0.0 Nm to 999.9 Nm / 0.0 In.lbs to 8848.7 In.lbs / 0.0 Ft.lbs to 737.4 Ft.lbs
Detection Threshold (Select From Graph)
[Functional overview]
The point in time when the tightening torque for a tightening angle of 1° reached not
less than this threshold is judged to be the snug point.
The value is automatically set by selecting one section on the graph.
This parameter is enabled only when the snug point setting is "Select From Graph."
Note
• If this threshold is set too high, snug point detection might not be made depending on work.
[Default value]
0.0 Nm/1°
[Setting value]
0.0 Nm/1° to 999.9 Nm/1° / 0.0 In.lbs/1° to 8848.7 In.lbs/1° / 0.0 Ft.lbs/1° to 737.4 Ft.lbs/1°
Entering the value with (*) will disable the function.
EN
The point in time when the tool started pulsing is
regarded as a snug point.
The point in time when tightening reached the set
torque is regarded as a snug point.
Select a desired snug point from the torque waveform
data.