2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Mode Setting
[Functional overview]
Select an operation mode of the tool.
[Default value]
Factory Default Mode (Fd)
[Setting value]
Wireless Communication Mode (C): The tool communicates with the controller to
Stand Alone Mode (A):
Shut-Off Torque
[Functional overview]
When the tightening torque reaches the set value of shut-off torque, the tool will stop
running automatically.
Ensure that it is in the range, Torque Upper Limit
[Default value]
EYFMH1: 20.0 Nm/177.0 In.lbs/14.7 Ft.lbs
EYFMH2: 50.0 Nm/442.5 In.lbs/36.9 Ft.lbs
[Setting value]
EYFMH1: 10.0 Nm to 70.0 Nm/88.5 In.lbs to 619.5 In.lbs/7.4 Ft.lbs to 51.6 Ft.lbs
EYFMH2: 30.0 Nm to 140.0 Nm/265.5 In.lbs to 1238.9 In.lbs/22.1 Ft.lbs to 103.2 Ft.lbs
Note
• The range where this tool guarantees performance is as follows:
EYFMH1: 20.0 Nm to 60.0 Nm/177.0 In.lbs to 531.0 In.lbs/14.7 Ft.lbs to 44.2 Ft.lbs
EYFMH2: 50.0 Nm to 120.0 Nm/442.5 In.lbs to 1061.9 In.lbs/36.9 Ft.lbs to 88.5 Ft.lbs
Torque Upper Limit
[Functional overview]
Set the upper limit of torque for judging work OK or NOK.
Ensure that it is in the range, Torque Upper Limit
[Default value]
*999.9 Nm/*8848.7 In.lbs/*737.4 Ft.lbs
[Setting value]
EYFMH1: 10.0 Nm to *999.9 Nm/88.5 In.lbs to *8848.7 In.lbs/7.4 Ft.lbs to *737.4 Ft.lbs
EYFMH2: 30.0 Nm to *999.9 Nm/265.5 In.lbs to *8848.7 In.lbs/22.1 Ft.lbs to *737.4 Ft.lbs
Entering the value with (*) will disable the function.
EN
send history logs and receive parameters.
The history log data is recorded in the internal
storage. The tool does not communicate with the
controller.
Shut-Off Torque