2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Detection Start Angle (Select From Graph)
[Functional overview]
Unless the accumulated tightening angle reaches this value, snug point detection does
not start.
This parameter is enabled only when the snug point setting is "Select From Graph."
[Default value]
0°
[Setting value]
0° to 99999°
Graph Sending/Storing Timing
[Functional overview]
Select the timing when the waveform data is sent to the controller or saved to the tool.
OFF:
After Every Fastening: The waveform data is saved to the tool or sent to the
After Batch Complete: The waveform data of all the work in a batch are sent together
NOK Only:
[Default value]
OFF
[Setting value]
OFF, After Every Fastening, After Batch Complete, NOK Only
Disable Reverse
[Functional overview]
When this function is ON, the tool will not operate reversely even if the trigger is on.
[Default value]
OFF
[Setting value]
ON, OFF
Entering the value with (*) will disable the function.
EN
The waveform data is discarded without being recorded. (The
work result data is recorded as usual.)
controller after each tightening work is completed.
to the controller after the batch is completed. (In "Wireless
Communication Mode" only)
Only in case of NOK, the waveform data of the work
concerned is saved to the tool or sent to the controller.
- 65 -