Télécharger Imprimer la page

Panasonic EYFMH1XC Instructions D'utilisation page 53

Publicité

Les langues disponibles

Les langues disponibles

2.2 USING THE TOOL MANAGER SOFTWARE
2.2.8 CONFIGURING PARAMETERS OF THE TOOL
(5) Set a Snug Point
The snug point is used as a reference point to divide angle measurements into the angle before snug
and the angle after snug.
The snug point can be set from three methods: [When Pulsing Starts], [Snug Torque], and [Select
From Graph].
Torque
█ When Pulsing Starts
The point in time when the tool started pulsing is regarded as a snug point. It is set just by selecting
the item.
█ Snug Torque
• The point in time when tightening reached the set torque is regarded as a snug point.
• After selecting the item of [Snug Torque], enter the value of [Detection Threshold].
█ Select From Graph
• Select a desired snug point from the torque waveform data.
• A rise in torque to a 1° increase in tightening angle at the selected point (a slope in graph) is the
threshold for determining the snug.
Note
• If there is a steeper slope in graph before the selected point, that point will be judged to be the
snug point.
• Select the item of [Select From Graph], and click [Select Snug Point].
The graph window opens.
EN
Select From Graph
Snug Torque
When Pulsing Starts
Free Run
Pulsing
- 53 -
Continued to the next page
Angle

Publicité

loading