Télécharger Imprimer la page

Panasonic EYFMH1XC Instructions D'utilisation page 25

Publicité

Les langues disponibles

Les langues disponibles

2.1 BASIC OPERATION
2.1.4 TIGHTENING CONFIRMATION LAMP AND COMMUNICATION LAMP
You can check the tightening result and the communication status by seeing the LED
lamps on the tool.
Tightening Confirmation Lamp Display
Lamp display
Lit for 2 s
Green
+ Buzzer (depending
on the setting)
Lit for 2 s
Red
+ Buzzer (depending
on the setting)
Lit continuously
Red
+ Buzzer
Blinking continuously
Orange
+ Buzzer
Lit continuously
Orange
+ Buzzer
EN
Tightening confirmation
lamp
Meaning of display
Details
The tightening work reached the set shut-
Work judged OK
off torque successfully.
The tightening work did not reach the set
shut-off torque.
For the cause of incompletion, check the
Work judged NOK
contents of the history log on the Tool
Manager software.
If any error is shown on the control panel
display, take action according to the error
Tool error
description.
Auto power-off
If the battery indication lamp is all blinking,
functioning
replace the battery pack.
The tool is locked because it reached
the maintenance timing that was set in
Maintenance
[Maintenance Interval Alarm].
Interval Alarm
Also check that the setting value (1 to
Lock Mode
99) and "0" are shown alternately on the
control panel display.
Take action according to the error
description shown on the control panel
Communication
display.
error
Also check "E9" shown on the control
Out of wireless
panel display.
communication
If it is correct, move into the wireless
range
communication range.
- 25 -
Refer to 2.2.12
Refer to 4.3.1
Refer to 2.2.10
Refer to 4.3.1

Publicité