2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Torque Lower Limit
[Functional overview]
Set the lower limit of torque for judging work OK or NOK.
Ensure that it is in the range, Torque Upper Limit
[Default value]
*0 Nm/*0 In.lbs/*0 Ft.lbs
[Setting value]
EYFMH1: *0 Nm to 70.0 Nm/*0 In.lbs to 619.5 In.lbs/*0 Ft.lbs to 51.6 Ft.lbs
EYFMH2: *0 Nm to 140.0 Nm/*0 In.lbs to 1238.9 In.lbs/*0 Ft.lbs to 103.2 Ft.lbs
Offset_Slope
[Functional overview]
This is a coefficient that adjusts the slope of the output torque curve of the tool to the
torque curve on the simulated actual workpiece.
For setting, you are recommended to use the automatic offset calculation function.
(How to set,
[Default value]
EYFMH1: 25.00
EYFMH2: 55.00
[Setting value]
0.10 to 500.00
Offset_Intercept
[Functional overview]
This is a coefficient that adjusts the intercept of the output torque curve of the tool to the
torque curve on the simulated actual workpiece.
For setting, you are recommended to use the automatic offset calculation function.
(How to set,
Note
• The value of offset (intercept) is the lower limit that the torque sensor can measure
with accuracy. Ensure that the set value of "Shut-Off Torque" and/or "Torque Lower
Limit" is not less than the value of offset (intercept).
[Default value]
EYFMH1: 5.00
EYFMH2: 5.00
[Setting value]
-1000.00 to 1000.00
Entering the value with (*) will disable the function.
EN
).
Refer to 2.2.8
).
Refer to 2.2.8
Shut-Off Torque
- 61 -
Torque Lower Limit.