Maintenance
8.4.1
Preparation
1.
Switch the pump off and secure it from being switched on
again.
2.
Reduce the pressure in the pipe system by opening a
consumer.
3.
Dismantle additional connections.
Pos: 184 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Pumpe/Anlage demontieren Multi @ 4\mod_1449582671417_370.docx @ 55626 @ 3 @ 1
8.4.2
Dismantling pump/unit
NOTICE
Depending on the installation conditions, the pump and motor size
are the deciding factors as to whether the pump unit should be
completely dismantled or just the motor unit.
1.
Loosen the piping from the suction and pressure lines.
2.
Loosen the motor feet (Normblock Multi) or pre-filter housing
(BADU Block Multi) screws from the foundation.
3.
Remove the complete pump/unit from the piping.
Pos: 185 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Motor demontieren Multi @ 4\mod_1449582708743_370.docx @ 55642 @ 3 @ 1
8.4.3
Dismantling the motor
WARNING
Risk of crushing due to the motor tilting.
Hang the motor on the lifting hooks or secure it from lifting.
1.
Loosen the fastening from the motor feet to the foundation if
necessary.
2.
Loosen the screws (914) on the coupling protection (681).
3.
Remove the coupling protection (681) from the drive lantern
(341).
4.
Loosen the hexagon screws (901.3).
5.
Push the lock washer (931) into the grooves on the motor
shaft.
6.
Tighten the hexagon screws (901.3).
7.
Loosen the hexagon socket screws (914.1).
8.
Loosen the nuts (920.5) on the motor flange.
9.
Lift off the motor (800).
Pos: 186 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Motoreinheit demontieren Multi @ 4\mod_1449582736998_370.docx @ 55658 @ 3 @ 1
42 EN
04/2016