Faults
Pos: 155 /Technische Dokumentation/Betriebsanleitung/Störung/Multi/Übersicht Multi @ 4\mod_1449582167130_370.docx @ 55369 @ 2 @ 1
7.1
Overview
Pos: 156 /Technische Dokumentation/Betriebsanleitung/Störung/Multi/Zu geringer Förderstrom der Pumpe @ 4\mod_1449582189147_370.docx @ 55385 @ @ 1
Fault: Too low a flow rate in the pump
Possible cause
Pumping against too high
a pressure.
Pump and pipes not
completely ventilated or
filled.
Intake or impeller
blocked.
Building of air sacks in
the piping.
Suction height too
large/Unit's NPSH
(intake) too low.
Drawing in air in the
mechanical seal.
Incorrect direction of
rotation.
Too low a speed.
Wear of components.
Running on two phases.
Pos: 157 /Technische Dokumentation/Allgemeine Module/#### Seitenumbruch #### @ 0\mod_1426069111812_0.docx @ 891 @ @ 1
34 EN
Solution
Set operating point again.
Check unit for impurities.
Vent.
Fill.
Remove impurities.
Modify piping or insert a
ventilation valve.
Correct liquid levels.
Install pump lower.
Completely open shut-off valve
in the intake.
If the resistance in the intake is
too large, modify the intake line.
Check basket/suction opening.
Observe the permitted pressure
reduction speed.
Replace mechanical seal.
Check the electrical connection
to the motor and switching
device.
Increase the voltage/frequency
on the frequency converter
within the permitted range.
Replace components.
Renew faulty fuse.
Check electrical power
connections.
04/2016