Installation
Pos: 134 /Technische Dokumentation/Betriebsanleitung/Installation/Aufstellung/Multi/Pumpe aufstellen und an die Rohrleitung anschließen @ 4\mod_1449581426810_370.docx @ 55174 @ 3 @ 1
5.3.1
Installing the pump and connecting it to the pipe
1.
When installing the pump, align the pump with the discharge
outlet using a spirit level.
2.
Clean and rinse the pump, pipes and connections thoroughly.
NOTICE
The motor can be damaged due to insufficient drainage!
Do not block or seal the drain gap between the pump housing
and the motor.
NOTICE
If it is sealed incorrectly, the thread can be damaged and the
sealing effect can be reduced!
Use Teflon tape for assembly.
NOTICE
The pump can be damaged by unauthorised mechanical strains
being placed on the pump!
Take the pipe up directly before the pump and connect it free
of tension.
3.
Connect the pipe free of tension according to the VDMA
standard sheet 24277. Use compensators.
4.
Ensure that any leaks cannot cause consequential damage.
Install a suitable retainer if necessary.
WARNING
Pumping medium hazardous to health!
Observe legal regulations regarding the disposal of media
hazardous to health.
Pos: 135 /Technische Dokumentation/Allgemeine Module/#### Seitenumbruch #### @ 0\mod_1426069111812_0.docx @ 891 @ @ 1
26 EN
04/2016