Pos: 176 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Saugsieb der BADU Block Multi reinigen @ 4\mod_1449582516229_370.docx @ 55546 @ 3 @ 1
8.2.1

Cleaning the BADU Block Multi strainer basket

1.
Switch pump off.
2.
Close shut-off valves.
3.
Drain the pre-filter housing (124) using the drain screw
(903.3).
4.
Unscrew star handle (925).
5.
Remove lid (160).
6.
Remove strainer basket (143).
7.
Hose strainer basket (143) down with water.
8.
Return strainer basket (143).
NOTICE
High concentration water treatment products can damage the
pump!
Do not place water treatment products, particularly in tablet
form, into the strainer basket.
NOTICE
Tightening the lid too tight will make it difficult to re-open the lid.
Only apply normal manual force.
9.
Replace and tighten the lid (160).
10. Open the shut-off valves.
11. Fill and ventilate the pump/unit. See chapter 6.1.2 on page
29.