Maintenance
9.
Remove the counter ring in the mechanical seal (433) from
the gland housing (161).
Pos: 191 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Pumpe/Anlage montieren Multi @ 4\mod_1449582816899_370.docx @ 55706 @ 2 @ 1
8.5
Assembling pump/unit
Pos: 192 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Voraussetzungen Multi @ 4\mod_1449582844929_370.docx @ 55722 @ 3 @ 1
8.5.1
Pre-requisites
Assemble using the exploded drawing attached.
Check O-rings, renew if necessary.
Tighten screws according to the torque indicated. See
chapter 8.6 on page 47.
Clean dismantled components and check them for wear.
Replace with original spare parts if necessary.
Sealing surfaces are clean and free of grease.
Pos: 193 /Technische Dokumentation/Betriebsanleitung/Wartung/Instandhaltung/Multi/Gleitringdichtung montieren Multi @ 4\mod_1449582875611_370.docx @ 55738 @ 3 @ 1
8.5.2
Assembling meachanical seal
NOTICE
Observe the following points:
–
Clean and careful working methods.
–
Only remove protection against contact on sliding surfaces
directly before assembly.
–
Use water as an assembly agent.
–
Never use oil or grease as an assembly agent.
1.
Clean the counter ring in the gland housing (161).
2.
Insert the counter ring carefully. Beware of applying pressure
evenly.
3.
Assemble the gland housing (161) on the drive lantern (341).
4.
Assemble the rotating insert in the mechanical seal (433) on
the impeller hub.
Pos: 194 /Technische Dokumentation/Allgemeine Module/#### Seitenumbruch #### @ 0\mod_1426069111812_0.docx @ 891 @ @ 1
44 EN
04/2016