2.5.6 Cable and connector for resolver connexion
resolver Cable
3x(2x0,34mm
Resolver cable
Type
Reference
Colour
Test voltage
Outside diameter
Dynamic radius of curvature
Alternating bending strength (R = 75 mm)
Oil resistance
Two types of connectors are possible (see Appendix 2 for dimensions and connection) :
Standard metal connector plug (right) - IP 66
Ref. 220036R4100
Pins to crimp (can be soldered).
Special metal connector plug (right) - IP 67
Ref. 220065R4621
Pins to solder.
2.6 Troubleshooting
Brushless servomotors PARVEX don't need preventive maintenance. The bearings have a double protection and are
life-greased.
Certain symptoms and their possible causes are listed below. This list is not comprehensive. Whenever an operating
incident occurs, consult the relevant servoamplifier installation instructions (the troubleshooting
display indications will help you in your investigation).
The resolver cable must be separated from the power cable.
Cables fitted with connectors may be provided by us : ask for details.
The cable is made up of 3 twisted pair shielded by pairs.
The pair shielding must be connected to the servoamplifier reference potential.
The 3 pairs are protected by general shielding which must be earthed (see
servoamplifier installation instructions).
The recommended cable can use resolver signals from up to 50 m away. For
greater distances ask for details.
Servoamplifier connection : comply with the relevant servoamplifier
installation instructions.
2
)
or
Pins to crimps.
:
:
:
:
:
:
:
:
220065R1621
CAR 0034
6537 P00 15
red, black markings
1 500 V
9,4 ± 0,2 mm
≥ 75 mm
≥ 5 million cycles
Very good