Installation and wiring
7.6.1 Electrical connections
number of fixed
type of connectors
connectors
1 male M12 fixed
female 5-pin M12 (available as an
connector
accessory)
1 male M12 fixed con-
female 5-pin M12 + male 5-pin M12
nector and 1 female M12
(both available as accessories)
fixed connector
7.6.2 Assembling the male or female
connector (accessories:
4
3
2
1
5
Fig. 11:  Multipin M12 connector (available as an accessory)
Unscrew the nut [1] on the body [4].
Insert the cable into the nut [1], the
cable clamp [2] and the seal [3], and
then into the body [4].
Strip 20 mm of the cable.
Cut the central wire (earth) so that
its length is equal to 11.5 mm.
Expose 5.5 mm of the wires on the
stripped cable.
Insert each wire into the appropriate
pin on the terminal block [5] (see
chap. 7.6.4 to 7.6.6).
Tighten the terminal block [5] wired
to the body [4].
Tighten the connector nut [1].
Pin of the female m12 connector available
as an accessory (order code 438680)
1
2
3
4
5
7.6.3 Equipotentiality of the installation
To ensure the equipotentiality of the installation (power supply -
device - fluid):
Connect together the various earth spots in the installation to
eliminate the potential differences that may occur between dif-
ferent earthes.
Observe faultless grounding of the shield of the power supply
cable.
Special attention has to be paid if the device is installed on
plastic pipes because there is no direct earthing possible.
Proper earthing is performed by earthing together the metallic
devices such as pumps or valves, that are as close as possible
to the device.
English
colour of the
wire
brown
white
blue
black
grey
21