Type 8026 - 8036 - SE36
Installation and wiring
Correct
Fig. 5:
Air bubbles within the pipe / Filling of the pipe
attention
risk of damage when installing the fitting.
▶ Respect the installation instructions given in the user manual for
the fitting.
→
Install the fitting S020 in the pipe so that the paddle wheel axis
of the device is horizontal (Fig. 6).
Fig. 6:
The paddle wheel axis must be horizontal
7.3.2 install the flowmeter 8026 into the
Incorrect
Fig. 7:
7.3.3 complete the installation of the 8026
→
Wire the device (see chap. 7.6) and supply power to the device.
→
Set the K-factor or determine it through a Teach-In procedure
(see chap. 8.8.8).
fitting S020
→
Check that there is a seal on the fitting
and that it is not damaged. Replace the
seal if necessary.
→
Place nut A on the fitting and insert
circlip B into the groove.
→
Carefully insert the device into the
fitting.
If assembly is correct, the device can
B
no longer rotate on itself.
→
Secure the unit with nut A, tightening
A
only by hand.
Installation of flowmeter 8026 into the fitting S020
English
17