6. Push the input/output modules (if applicable) in the original
order and then the left E end plate (2) onto the tie rods (5)
and screw into place (each with 2 DIN 912–M4 hexagonal
socket-head screws (1), wrench size 3).
Tightening torque: 2.5 to 3.0 Nm.
7. Make all the presettings on the new bus coupler (4)
(see "Making presettings" on page 101).
8. Reestablish the connections.
9. Check the configuration and adjust it if necessary
(see "Configuring the bus coupler with WinDP" on page 111).
8.2

Mounting input/output module(s)

Input and output modules can be added to the valve system.
Applied voltage and high pressure!
Danger of injury from electric shocks and sudden pressure
drops.
O
Make sure that the system is not under voltage or
pressure.
Open inputs/outputs
Danger of electric shocks caused by contact, short circuits, or
damage to the system.
O
Always close unused inputs or outputs with M12 and M8
protective caps (see accessories) to comply with the
IP 65 protection class.
Disassembly and Exchange
CAUTION
CAUTION
131