Aventics PROFIBUS DP Mode D'emploi page 132

Masquer les pouces Voir aussi pour PROFIBUS DP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 141
132
AVENTICS | PROFIBUS DP | R499050016–BDL–001–AE
Disassembly and Exchange
1
2
Fig. 22: Mounting input/output modules on the VS HF03 LG or the VS HF04, example
1 Hexagonal socket-head screws
2 E end plate
3 Seal
4 Output module
6
3
4
3
A maximum of 6 modules (input or output) may be mounted
on one valve system. Observe the permissible current load!
Observe Figure 22 on page 132.
1. Unscrew the E end plate (2) from the bus coupler (7) or from
the last input (5) or output module (4) of the valve system
(2 DIN 912 – M4 hexagonal socket-head screws (1), wrench
size 3) and remove it from the tie rods (6).
2. Screw the tie rods (6) for the input (5) or output modules (4) on
the existing tie rods (6) (2 per input (5) or output module (4)).
– Ensure that the tie rods (6) are flush with the surface!
7
6
3
5
5 Input module
6 Tie rod
7 Bus coupler