Commissioning and Operation
Tab. 13:
Assignment of the S4, S5, and S6 switches
Switches
S4
S5
S6
S6

7.1.4 Assigning the valve supply

The S4, S5, and S6 switches for assigning the valve supply are
located beneath PG fitting B (see Figure 9). The following is
assigned to each switch:
W
4 subbase positions for double solenoid valves
(with solenoids 12 and 14) or
W
8 subbase positions for single solenoid valves
(with solenoid 14).
Fig. 9:
S4, S5, S6 switches for assigning valve supply voltages (U
This switch allows valves to be assigned in groups to supply
voltages U
When delivered, all valves are assigned to the U
Subbase positions
for double solenoid
valves (solenoids 12, 14)
0
1 – 4
1
5 – 8
2
9 – 12
2
9 – 12
3
13 – 16
When delivered, switches S4 to S6
are in the U
and U
.
Q1
Q2
position.
Q1
ON
OF F
S7
S8
U
Q1
U
Q2
S4 S5 S6
Q1
Subbase positions
for single solenoid
valves (solenoid 14)
1 – 8
09 – 16
17 – 24
17 – 24
25 – 32
, U
)
Q1
Q2
voltage.