6.3.4.1 Terminal Assignment - External Enable Signal - Ecolab EcoPro-ES-00510X-PFC-00S-1S-S0 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 184

6.3.4.1 Terminal assignment - External enable signal

The terminals are accessible after dismantling the front cover, (see
6.3.4 'Electrical Installation' on page 42, Fig. 14, 2).
In accordance with the terminal assignment given below, modifications can be made to
control inputs at the customer's site.
NOTICE!
All changes to the terminal assignment are only approved by skilled personnel.
In the event of queries and requests for help, please contact our customer
service department.
Fig. 15: EcoPro terminal assignment ''
L1 Mains phase (live conductor)
N
Neutral (earth)
Permissible external diameters for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm (pos. 2-5).
Permissible cable: LIYY 4x0.5; LIYY 5x0.34; LYCY 2x0.34; Oilflex 4x0.5
Assembly, installation, modification and upgrades
8
9
43
Ä Chapter
Enable signal, earth (GND)
Enable signal, signal input
417102264 Rev. 5-01.2019