Technical data

determined in accordance with EN 16129:2013 or Truma test
conditions
Gas type
Liquefied gas (propane / butane)
Admission pressure
0.6 – 16 bar
Output pressure
30 mbar
Nominal changeover pressure (p
750 mbar
Regulator capacity
1.5 kg/h
Regulator inlet
Male thread M20 x 1.5 (G.13)
Regulator outlet
Olive screw connection, 8 mm or 10 mm (H.9)
Recommended tightening torque
3 – 5 Nm for union nut M20 x 1.5 (G.13)
Operating temperature
-20 °C to +50 °C
Product ID number
CE-0085BQ0102
Subject to technical changes.
)
di

Installation instructions

The unit may only be installed and re-
paired by an expert. Read the installation
instructions carefully before working, and
then comply with them!
Disregarding installation instruc-
tions or incorrect installation can
put people in danger and cause dam-
age to property.

Safety instructions

– Residual gas: No smoking, no naked flames!
– In the case of caravans and motor homes with 30 mbar
consumers, the maximum pressure loss ΔP of the down-
stream installation to the consumer must not exceed
5 mbar (ΔP5).
– In order to ensure that the equipment operates correctly, the
gas pressure regulation system must be securely screwed
to a stable wall / ceiling (with 4 screws).
– Attention must be paid to the installation position.

Protection against dirt / oil

A Truma gas filter must be installed in front of each gas pressure
regulation system inlet in order to reliably protect it against dirt /
oil. A set of operating and installation instructions is supplied
with the gas filter.