Symbols Used; Proper Use; Technical Data - Truma MonoControl CS Mode D'emploi

Masquer les pouces Voir aussi pour MonoControl CS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

External gas socket

Symbols used

Symbol indicates possible hazards.

Proper use

The external gas socket is approved solely for installation and
opera-tion in caravans of Vehicle Class O and motor caravans
of Vehicle Class M1.

Technical data

Dimensions (L x H x P)
145 x 107 x 28 mm
Operating pressure
30 / 50 mbar
Operating instructions
When external gas equipment is being connected, the
operating pressure of the gas supply of 30 or 50 mbar must
correspond with the operating pressure of the equipment that
is being connected (see type plate).
The plug-in connection can only be made if the quick-acting
valve is closed. The safety locking mechanism can be released
by sliding back the coupling sleeve.
The coupling K-valve is designed such that the quick-acting
valve can only be opened if the connection is being made via
the plug-in connection. The connection is made by inserting
the plug-in connection into the safety coupling.
This operation can be carried out using one hand. After un-
coupling the equipment, seal off the valve opening using the
protection cap.
The external gas socket is only suitable for remov-
ing gas, not for feeding gas into the gas system.
Fig. 1
Fig. 2
EN
3