Installationandwiring
Fluid pressure
P (bar)
16
15
14
13
12
PVDF
11
10
9
8
PVC + PP
7
6
5
4
3
2
1
0
-20
0
A : range of use for the complete device
Fig. 3:
Fluid pressure /temperature dependency curves
Type 8011
A
Metal (PN16)
PVDF (PN10)
PVC + PP
(PN10)
PP (PN10)
+20
+40
+60
+80
+100 +120
Fluid temperature
7.2.
installation onto the pipe
danger
Danger due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and drain the
pipe before loosening the process connections.
Danger due to high temperatures of the fluid.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before loosening
the process connections.
Danger due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention and
safety relating to the use of aggressive fluids.
7.2.1.
recommandations for installing the
8011 on the pipe
T ( ° C)
Check that the DN of the fitting is dimensioned to the process
according to the graphs in chap. 7.3.
→
Install the device on the pipe in such a way that the upstream
and downstream distances are respected according to the
design of the pipes, as per Fig. 4 and the EN ISO 5167-1
standard.
English
23