GYS ENERGY STATION Notice Originale page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
CHARGING OF THE EXTERNAL BATTERIES.
The charger can charge 12V batteries with liquid or gel electrolyte of 35 Ah to 225Ah.
In 12V mode: to quickly charge the external batteries, it is advised the internal battery of the chosen output is fully
charged.
In 24V mode: it is imperative to have the battery fully charged.
To charge the external batteries:
TROUBLESHOOTING
The Vehicle does not start
1
Intense sparks when connecting the
clamps to the vehicle battery.
2
The internal batteries are charged, the
starting voltage choice is right, but the
3
vehicle does not start.
The red light blinks (after 24h of
charge)
1
The green and orange lights blink turn
by turn while charging.
2
14
ENERGY STATION
- Permanent orange light: charge – battery voltage increase. (12 hours max)
- Blinking orange light – voltage regulation (2h or 24 hours if the battery is sulfated)
- Green light: battery charged. Starting possible. Let the machine plugged to the mains if not
used.
• When the battery is charged, switch off « 0 »
• Unplug the the power supply cable
• Disconnect the clamps
• Connect the cables to the required 12V or 24V outputs (output 1 or 2).
• Connect the clamps: Red clamp on the battery "+" and black clamp on the "–"..
• Suivre la démarche de recharge des batteries internes.
ANOMALIES
The internal batteries are discharged.
Several starting were attempted wit-
hout break.
Voltage error
Voltage error
Polarity reversal.
Vehicle problem (rectifier, starter, glow
plugs...)
The battery does not charge or its vol-
tage does not increase enough.
Charger thermal protection.
CAUSES
Check the internal batteries condition
by pressing the test keys. Charge if
necessary.
Wait for 3 minutes between 2 star-
ting attempts. A starting must not last
more than 7 seconds.
Check the starting voltage selected
matches the vehicle battery voltage.
Check the connections and that the
starting voltage matches the selected
voltage.
Connect the red cable to the (+) batte-
ry terminal and the black cable to the
(-) terminal.
Take contact with a professional.
Check the collars are well tightened on
the battery terminals. Clean the ter-
minals and restart the charge. If the
red light blinks again, the batteries are
damaged.
Wait for several minutes (5 to 10 mi-
nutes) to cool the machine. The charge
will automatically restart as soon as
the temperature will have decreased
enough.
EN
REMEDIES

Publicité

Table des Matières
loading

Table des Matières