ChECKiNG/REpLACiNG
ThE CARBON BRUShES
wARNiNG: Disconnect the machine from the
power supply before attempting to check or
replace the Carbon Brushes.
Replace both carbon brushes if either has less
than 6mm. length of carbon remaining, or if
the spring or wire is damaged or burned.
To remove the brushes:
• Unscrew the plastic caps found at the back
of the motor.
Be careful as the caps are spring-loaded.
• Withdraw the brushes with their springs.
• If replacement is necessary renew the
brushes and replace the caps.
Note: Used but serviceable brushes can
be replaced, but only as long as they are
returned to the same position, and inserted
the same way round, as they were removed
from the machine.
• Run new brushes without load for
approximately 5 minutes. This will help
the bedding-in process.
www.evolutionpowertools.com
TABLE iNSERT
A one piece table insert is fitted to this
machine. If it is damaged or worn, it must be
replaced. Replacement inserts are available
from Evolution Power Tools.
To replace the table insert:
• Remove the cross-head screws that secure
the insert to the rotary table.
Note: It may be necessary to temporarily
remove or reposition the fence to gain
access to some of the fixing screws.
• Lift the insert from the table.
• Remove any debris that may have
accumulated under the insert.
• Fit the replacement insert, and replace the
fixing screws.
• If necessary replace and re-align the fence.
(See FENCE ALiGNMENT and Fig 17)
• Check that the insert is lying flush and level
within the table.
ENViRONMENTAL pROTECTiON
(6.4)
Waste electrical products should not be
disposed of with household waste. Please
recycle where facilities exist. Check with your
Local Authority or retailer for recycling advice.
30