• If adjustment is necessary, loosen the two Fence adjustment
screws using a Hex Key.
• Re-position the Fence in its elongated slots until alignment
is achieved.
• Securely tighten the socket head Hex screws.
Note: To gain access to the Left Hand (LH) machine screw it
may be necessary to remove the sliding upper portion of the
fence from the main fence casting.
To remove the upper sliding fence:
• Remove the grub screw (Fig 19) which holds the sliding
upper part of the fence 'captive' to the main fence casting.
• Slide the sliding upper fence from the main fence casting.
• The socket headed machine screw should now be
easily accessible.
• Reposition the Fence until the correct alignment is achieved,
and then retighten the socket head machine screws.
• Recheck the alignment.
• Reinstall the sliding upper portion of the fence.
Note: Reinstallation is the reversal of the removal process.
OpERATiNG iNSTRUCTiONS
(8.1)
Caution: The Mitre Saw should be inspected (particularly for
the correct functioning of the safety guards) before each use.
Do not connect the saw to the power supply until a safety
inspection has been carried out.
Ensure that the operator is adequately trained in the use,
adjustment and maintenance of the machine, before
connecting to the power supply and operating the saw.
(8.2) wARNiNG: To reduce the risk of injury, always unplug
the saw before changing or adjusting any of the machines
parts. Compare the direction of the rotation arrow on the
guard to the direction arrow on the blade. The blade teeth
should always point downward at the front of the saw. Check
the tightness of the arbor screw.
Fig. 19