GYS PROTIG 201 AC/DC Mode D'emploi page 23

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
PROTIG 201 AC/DC - PROTIG 201L AC/DC
EN
PROTIG 201
PROTIG 201L
PROTIG 201
PROTIG 201L
045675
045682
039704
041257
038271
038202
ACTIVATION OF THE VRD FUNCTION (VOLTAGE REDUCTION DEVICE)
This device protects the welder. The welding current is delivered only when the electrode is in contact with the part (low
resistance). As soon as the electrode is removed, the VRD function lowers the voltage to a very low value.
The VRD function is originally disabled. However, this can be activated by means of an ON/OFF switch on the power
source control board. To access it, follow the steps below:
1. DISCONNECT THE PRODUCT FROM THE POWER SUPPLY BEFORE HANDLING.
2. Remove the screws to take the power source cover off.
3. Locate the switch on the control board (red box on diagram below - n° 2).
4. Turn the switch located on this control card ON. The red LED switches off.
5. The VRD function is activated.
6. Screw the power source cover back on.
7. On the interface (HMI), the LED for the VRD function is lighted :
To deactivate the VRD function, simply turn the switch located on the control board back to OFF. The VRD LED on the
HMI is turned off :
2
1
RESETTING THE WELDING STATION
It is possible to restore the factory settings of the welding machine. When the station is in sleep mode, press the sleep
exit push button for 3 seconds. The station then displays "3", "2", "1" and then resets the unit.
23